4820-01-119-5114 VALVE,CALIBRATED FLOW Index 4820-01-119-5116 VALVE,GLOBE

National Stock Number:
4820-01-119-5115

Federal Supply Class:
4820

National Item Identification Number:
011195115

Description:
VALVE,GLOBE

Detail:
A valve with one inlet and one outlet connection with outlet flow parallel to inlet flow. The flow is controlled by the action of a stem which lifts the disk perpendicularly off the center axis of its seat. The stem is at a 90 degree (1.5708 radians) angle to axis of flow. Excludes VALVE, STOP-CHECK; COCK, SHUTOFF, SCREW STEM; and VALVE, SOLENOID.


Manufacturer Information:
1513G4S28968CIRCOR INSTRUMENTATION TECHNOLOGIES, INC.
1513G4Y28968CIRCOR INSTRUMENTATION TECHNOLOGIES, INC.
167528968CIRCOR INSTRUMENTATION TECHNOLOGIES, INC.
464JM0D128968CIRCOR INSTRUMENTATION TECHNOLOGIES, INC.


Techincal Specification:
BONNET TYPEINSIDE SPRING
BONNET ATTACHMENT METHODTHREADED
CONNECTION STYLEFLARELESS (TUBE) ALL ENDS
CONNECTION TYPETHREADED EXTERNAL TUBE ALL ENDS
FEATURES PROVIDEDBONNET PACKING
FLOW CONTROL DEVICESTEM
MATERIALRUBBER PACKING
MATERIALSTEEL COMP 303 BODY
MATERIALSTEEL COMP 303 FLOW CONTROL DEVICE
MAXIMUM OPERATING TEMP300.0 FAHRENHEIT SINGLE RESPONSE
NOMINAL THREAD SIZE0.438 INCHES ALL ENDS
OPERATING PRESSURE200.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM SINGLE RESPONSE
SEAT ANGLE12.0 DEGREES ALL ENDS
VALVE OPERATION METHODMANUAL
STYLE DESIGNATORSTRAIGHT THRU
THREAD CLASS2A ALL ENDS
THREAD DIRECTIONRIGHT-HAND ALL ENDS
THREAD SERIES DESIGNATORUNF ALL ENDS


Click here to Register for Free 30-day Trial