4820-00-788-2941 VALVE,REGULATING,FLUID PRESSURE Index 6625-00-788-2946 MULTIMETER

National Stock Number:
4820-00-788-2942

Federal Supply Class:
4820

National Item Identification Number:
007882942

Description:
VALVE,REGULATING,FLUID PRESSURE

Detail:
A valve designed to automatically maintain within close limits a predetermined outlet pressure which may be adjustable within a specified range regardless of the higher fluctuating or constant inlet pressure. It is designed for use with compressed gas(es) and various liquids and may include gauges. It may be inline or cartridge (manifold) design. Excludes REGULATOR, PRESSURE, MEDICAL GAS ADMINISTRATION APPARATUS; REGULATOR, OXYGEN, BAROMETRIC CONTINUOUS FLOW; REGULATOR, OXYGEN DEMAND; REGULATOR, OXYGEN DILUTER DEMAND; and valve(1), fluid pressure regulating, aircraft.


Manufacturer Information:
217754-199657MAROTTA CONTROLS INC
919477018876U S ARMY AVIATION AND MISSILE COMMAND


Techincal Specification:
END CONNECTION QUANTITY2
BODY STYLESTRAIGHT THRU W/OFFSET
FILTERINCLUDED
FIRST END CONNECTION TYPETHREADED EXTERNAL TUBE
FIRST END STYLE DESIGNATORFLARED
FIRST END THREAD CLASS3A
FIRST END THREAD DIRECTIONRIGHT-HAND
FIRST END OUTSIDE DIAMETER TUBE ACCOMMODATED0.250 INCHES NOMINAL
FIRST END SEAT ANGLE IN DEG37.0
FLOW CONTROL DEVICEDISK
OUTLET PRESSURE RANGE5.0 TO 3000.0 CAMERA MOUNT
MANUAL CONTROL METHODKNOB
MATERIALALUMINUM AND BRONZE SEAT
MAXIMUM INLET PRESSURE RATINGERR-060
MOUNTING FACILITYPANEL
OFFSET DISTANCE0.365 INCHES NOMINAL
REGULATION TYPEMANUAL SINGLE STAGE
SECOND END RELATIONSHIP WITH FIRST ENDIDENTICAL
VALVE LOADING METHODSPRING
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONMIL-STD-171,FINISH NO. 7.2.1 MIL SPEC SINGLE TREATMENT RESPONSE OUTSIDE
SURFACE TREATMENTANODIZE OUTSIDE
TEMP RATING125.0 FAHRENHEIT NOMINAL
THREAD SIZE AND SERIES/TYPE DESIGNATOR7/16-20 UNF FIRST END


Click here to Register for Free 30-day Trial