| CONNECTION TYPE | FLANGE 1ST END |
| CONNECTION STYLE | PLAIN (TUBE) 2ND END |
| CONNECTION TYPE | UNTHREADED INTERNAL TUBE 2ND END |
| CURRENT RATING IN AMPS | 0.300 |
| FACE TO FACE DISTANCE | 7.583 INCHES |
| FEATURES PROVIDED | MANUAL OVERRIDE |
| FLANGE FACE DESIGN | RECESSED STRAIGHT 1ST END |
| FLANGE SHAPE | ROUND 1ST END |
| FREQUENCY IN HERTZ | 400.0 |
| MAXIMUM OPERATING PRESSURE | 0.8 POUNDS PER SQUARE INCH SINGLE RESPONSE |
| PROPRIETARY CHARACTERISTICS | PACS |
| MAXIMUM OPERATING TEMP | 165.0 DEG FAHRENHEIT SINGLE RESPONSE |
| MEDIA FOR WHICH DESIGNED | AIR SINGLE RESPONSE |
| NOMINAL OUTSIDE DIAMETER TUBE ACCOMMODATED | 7.900 INCHES 2ND END |
| NOMINAL OUTSIDE DIAMETER | 8.500 INCHES 1ST END |
| NOMINAL THICKNESS | 0.125 INCHES 1ST END |
| RECESS NOMINAL DEPTH | 0.083 INCHES 1ST END |
| RECESS NOMINAL DIAMETER | 8.411 INCHES 1ST END |
| SPECIAL FEATURES | SERVES AS SHUTOFF VALVE FOR CONDITIONED AIR,CONTROLLED BY ELECTRO-MECHANICAL ACTUATOR; HEIGHT-15.6 IN.,WIDTH-9.4 IN.,DEPTH-7.583 IN.; BURST PRESSURE-3.5 PSIG AT 165 DEG F; PROOF PRESSURE-2.0 PSIG AT 165 DEG F;DUTY CYCLE-CONTINUOUS; OPENING/CLOSING TIME--20 TO 30 SECONDS |
| VALVE OPERATION METHOD | ELECTRIC MOTOR |
| VALVE SIZE | 7.910 INCHES |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 104.0 AC AND 122.0 AC |
| STYLE DESIGNATOR | STRAIGHT THRU FLANGED ENDS |