STYLE DESIGNATOR | STRAIGHT THRU |
MEDIA FOR WHICH DESIGNED | AIR SINGLE RESPONSE |
MAXIMUM OPERATING PRESSURE | 225.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
MAXIMUM OPERATING TEMP | 67.0 DEG FAHRENHEIT SINGLE RESPONSE |
VALVE OPERATION METHOD | SOLENOID |
VOLTAGE IN VOLTS AND CURRENT TYPE | 23.0 DC AND |
| 30.0 DC |
CURRENT RATING IN AMPS | 1.000 |
FLOW CONTROL DEVICE NORMAL OPERATION POSITION | CLOSED |
CONNECTION TYPE | UNTHREADED INTERNAL TUBE 1ST END |
| FLANGE 2ND END |
CONNECTION STYLE | PLAIN (TUBE) 1ST END |
FLANGE SHAPE | RECTANGULAR 2ND END |
NOMINAL THICKNESS | 0.190 INCHES 2ND END |
NOMINAL LENGTH | 1.380 INCHES 2ND END |
NOMINAL WIDTH | 1.380 INCHES 2ND END |
BOLT HOLE QUANTITY | 4 2ND END |
CENTER TO CENTER NOMINAL DISTANCE BETWEEN BOLT HOLES ALONG LENGTH | 1.062 INCHES 2ND END |
CENTER TO CENTER NOMINAL DISTANCE BETWEEN BOLT HOLES ALONG WIDTH | 1.062 INCHES 2ND END |
FLANGE FACE DESIGN | PLAIN 2ND END |
NOMINAL OUTSIDE DIAMETER TUBE ACCOMMODATED | 1.000 INCHES 1ST END |
APERTURE DIAMETER | 0.100 INCHES NOMINAL |
SPECIAL FEATURES | KEYWAY IN ELECTRICAL RECEPTACLE OPPOSITE TO FLOW |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 07797 |
DESIGN CONTROL REFERENCE | 2100607-2 |