| END CONNECTION DESIGN | ELBOW SECOND END |
| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END FITTING COMPONENT AND MATERIAL | COMPLETE FITTING STEEL ALL ENDS |
| END FLANGE CONSTRUCTION | SOLID FIRST END |
| END FLANGE CONSTRUCTION | SOLID SECOND END |
| BURST TEST PRESSURE | 12000.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | PLAIN SWIVEL FIRST END |
| CONNECTION STYLE | PLAIN SWIVEL SECOND END |
| CONNECTION TYPE | PLAIN FACE FLANGE FIRST END |
| CONNECTION TYPE | PLAIN FACE FLANGE SECOND END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLANGE OUTSIDE DIAMETER | 1.750 INCHES NOMINAL FIRST END |
| FLANGE OUTSIDE DIAMETER | 1.750 INCHES NOMINAL SECOND END |
| FLANGE THICKNESS | 1.000 INCHES NOMINAL FIRST END |
| FLANGE THICKNESS | 1.000 INCHES NOMINAL SECOND END |
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES FIRST END |
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES SECOND END |
| FLOW ANGLE | 90.0 DEGREES SECOND END |
| HYDROSTATIC TEST PRESSURE | 6000.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 1.000 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER SPIRALLY LAID STEEL WIRE AND 2ND LAYER SPIRALLY LAID STEEL WIRE AND 3RD LAYER SPIRALLY LAID STEEL WIRE AND 4TH LAYER SPIRALLY LAID STEEL WIRE AND OUTER LAYER MOLDED RUBBER, SYNTHETIC |
| OPERATING PRESSURE | 3000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| OUTSIDE DIAMETER | 1.560 INCHES NOMINAL |
| MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
| MEASURING METHOD AND LENGTH | 76.000 INCHES NOMINAL WORKING |
| MINIMUM INSIDE BENDING RADIUS | 11.000 INCHES |
| SPECIAL FEATURES | INNER CONVEYING TUBE MATERIAL-RUBBER, SYNTHETIC |
| SPECIFICATION/STANDARD DATA | SAE J517,100R9,TYPE A NATIONAL STD/SPEC |
| TEMP RATING | -40.0 FAHRENHEIT AND 212.0 FAHRENHEIT SINGLE RESPONSE |