| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END CONNECTION DESIGN | STRAIGHT SECOND END |
| END FLANGE CONSTRUCTION | SOLID SECOND END |
| BURST TEST PRESSURE | 4000.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | SWIVEL NUT FLARE FIRST END |
| CONNECTION TYPE | RAISED FACE FLANGE SECOND END |
| CONNECTION TYPE | THREADED INTERNAL TUBE FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES SECOND END |
| HYDROSTATIC TEST PRESSURE | 2000.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 0.750 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | CONVOLUTED |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER SPIRALLY WRAPPED POLYTETRAFLUOROETHYLENE IMPREGNATED GLASS FIBER AND OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
| OUTSIDE DIAMETER | 1.090 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 12.000 INCHES NOMINAL WORKING |
| MINIMUM INSIDE BENDING RADIUS | 2.500 INCHES |
| NOMINAL THREAD SIZE | 1.062 INCHES FIRST END |
| OPERATING PRESSURE | 1000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| SEAT ANGLE | 37.0 DEGREES FIRST END |
| TEMP RATING | -65.0 FAHRENHEIT AND 400.0 FAHRENHEIT SINGLE RESPONSE |
| THREAD CLASS | 3B FIRST END |
| THREAD DIRECTION | RIGHT-HAND FIRST END |
| THREAD QUANTITY PER INCH | 12 FIRST END |
| THREAD SERIES DESIGNATOR | UN FIRST END |