| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END FLANGE CONSTRUCTION | SOLID FIRST END |
| BOLT CIRCLE DIAMETER | 2.688 INCHES NOMINAL FIRST END |
| BOLT HOLE DIAMETER | 0.562 INCHES NOMINAL FIRST END |
| BOLT HOLE QUANTITY | 4 FIRST END |
| BURST TEST PRESSURE | 3600.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | RAISED FIRST END |
| CONNECTION TYPE | RAISED FACE FLANGE FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLANGE OUTSIDE DIAMETER | 3.821 INCHES NOMINAL FIRST END |
| FLANGE THICKNESS | 0.345 INCHES NOMINAL FIRST END |
| FLANGE STYLE | ROUND W / BOLT HOLES FIRST END |
| HYDROSTATIC TEST PRESSURE | 1800.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 0.785 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | CONVOLUTED |
| LAYER COMPOSITION AND LOCATION | OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
| OUTSIDE DIAMETER | 1.075 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 28.000 INCHES NOMINAL OVERALL |
| MINIMUM INSIDE BENDING RADIUS | 3.750 INCHES |
| OPERATING PRESSURE | 1000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| RAISED FACE DIAMETER | 1.750 INCHES NOMINAL FIRST END |
| RAISED FACE HEIGHT | 0.113 INCHES NOMINAL FIRST END |
| SPECIAL FEATURES | TWO HOSE ASSEMBLIES CONNECTED BY 90 DEG ELBOW, FIRST AND SECOND LEG LG IDENTICAL, 14.000 IN. LONG |
| TEMP RATING | -65.0 FAHRENHEIT AND 400.0 FAHRENHEIT SINGLE RESPONSE |