| BURST TEST PRESSURE | 9000.0 POUNDS PER SQUARE INCH |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLOW ANGLE | 90.0 DEGREES SECOND END |
| HYDROSTATIC TEST PRESSURE | 6000.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 0.650 INCHES MINIMUM |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED CORROSION RESISTANT STEEL WIRE AND 2ND LAYER SPIRALLY LAID CORROSION RESISTANT STEEL WIRE AND 3RD LAYER SPIRALLY LAID CORROSION RESISTANT STEEL WIRE AND 4TH LAYER SPIRALLY LAID CORROSION RESISTANT STEEL WIRE AND 5TH LAYER SPIRALLY LAID CORROSION RESISTANT STEEL WIRE AND OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
| OUTER COVERING ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FUEL RESISTANT AND OIL RESISTANT |
| OUTSIDE DIAMETER | 1.070 INCHES MAXIMUM |
| MEASURING METHOD AND LENGTH | 51.375 INCHES NOMINAL OVERALL |
| MINIMUM INSIDE BENDING RADIUS | 7.750 INCHES |
| OPERATING PRESSURE | 3000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| SEAT ANGLE | 12.0 DEGREES SECOND END |
| SPECIAL FEATURES | INNER CONVEYING TUBE MATERIAL-PLASTIC, POLYTETRAFLUOROETHYLENE |
| SPECIFICATION/STANDARD DATA | AS604-81343 NATIONAL STD/SPEC |
| THREAD SERIES DESIGNATOR | UN FIRST END |