| END CONNECTION DESIGN | STRAIGHT FIRST END |
| BURST TEST PRESSURE | 5000.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | FLARELESS FIRST END |
| CONNECTION TYPE | THREADED EXTERNAL TUBE FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| EXTERIOR COLOR | NATURAL |
| HYDROSTATIC TEST PRESSURE | 2500.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 0.875 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED CORROSION RESISTANT STEEL WIRE AND OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
| OPERATING PRESSURE | 1250.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| OUTER COVERING ENVIRONMENTAL PROTECTION | FUEL RESISTANT AND SALT WATER RESISTANT AND WEATHERPROOF |
| OUTSIDE DIAMETER | 1.125 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 51.934 INCHES MINIMUM OVERALL AND 52.666 INCHES MAXIMUM OVERALL |
| MINIMUM INSIDE BENDING RADIUS | 7.375 INCHES |
| NOMINAL THREAD SIZE | 1.312 INCHES FIRST END |
| NONDEFINITIVE SPEC/STD DATA | 1 CLASS |
| SEAT ANGLE | 12.0 DEGREES FIRST END |
| SPECIFICATION/STANDARD DATA | 81349-MIL-H-25579 GOVERNMENT SPECIFICATION |
| TEMP RATING | -67.0 FAHRENHEIT AND 450.0 FAHRENHEIT SINGLE RESPONSE |
| THREAD CLASS | 3A FIRST END |
| THREAD DIRECTION | RIGHT-HAND FIRST END |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL JOINT (UNJ) FIRST END |
| THREAD QUANTITY PER INCH | 12 FIRST END |