| END CONNECTION DESIGN | STRAIGHT FIRST END |
| BURST TEST PRESSURE | 24000.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | EXTERNAL SEAT FOR GASKET SEAL (BOSS) FIRST END |
| CONNECTION TYPE | THREADED EXTERNAL BOSS FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FEATURES PROVIDED | ELECTROSTATIC DISCHARGE CAPABILITY |
| HYDROSTATIC TEST PRESSURE | 1200.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 0.440 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED CORROSION RESISTANT STEEL WIRE AND 2ND LAYER SPIRALLY WRAPPED CORROSION RESISTANT STEEL FABRIC AND 3RD LAYER SPIRALLY WRAPPED CORROSION RESISTANT STEEL FABRIC AND OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
| OUTSIDE DIAMETER | 0.800 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 15.500 INCHES NOMINAL OVERALL |
| MINIMUM INSIDE BENDING RADIUS | 8.000 INCHES |
| NOMINAL THREAD SIZE | 1.750 INCHES FIRST END |
| OPERATING PRESSURE | 6000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| SPECIAL FEATURES | INNER CONVEYING TUBE MATERIAL-PLASTIC, POLYTETRAFLUOROETHYLENE |
| TEMP RATING | -450.0 FAHRENHEIT SINGLE RESPONSE |
| THREAD CLASS | 3A FIRST END |
| THREAD DIRECTION | RIGHT-HAND FIRST END |
| THREAD QUANTITY PER INCH | 12 FIRST END |
| THREAD SERIES DESIGNATOR | UN FIRST END |