| END CONNECTION DESIGN | STRAIGHT FIRST END |
| BURST TEST PRESSURE | 12000.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | CAM OR LEVER (EXTERNAL) FIRST END |
| CONNECTION TYPE | EXTERNAL QUICK DISCONNECT FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FEATURES PROVIDED | ELECTROSTATIC DISCHARGE CAPABILITY |
| HYDROSTATIC TEST PRESSURE | 6000.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 0.188 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED COTTON CORD AND 2ND LAYER BRAIDED STEEL WIRE AND OUTER LAYER RUBBER IMPREGNATED BRAIDED COTTON CORD |
| OUTER COVERING ENVIRONMENTAL PROTECTION | WATER RESISTANT |
| OUTSIDE DIAMETER | 0.453 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 144.000 INCHES NOMINAL EXCLUDING END FITTINGS |
| MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
| OPERATING PRESSURE | 3000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| QUICK DISCONNECT NOMINAL SIZE | 0.250 INCHES FIRST END |
| TEMP RATING | -65.0 FAHRENHEIT AND 158.0 FAHRENHEIT SINGLE RESPONSE |