CONNECTION TYPE | THREADED EXTERNAL PIPE 1ST END |
| THREADED INTERNAL TUBE 2ND END |
MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
MEASURING METHOD AND LENGTH | 52.400 INCHES MINIMUM RANDOM AND |
| 52.850 INCHES MAXIMUM RANDOM |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
TEMP RATING | -65.0 DEG FAHRENHEIT AND |
| 250.0 DEG FAHRENHEIT SINGLE RESPONSE |
MAXIMUM OPERATING PRESSURE | 800.0 POUNDS PER SQUARE INCH |
HYDROSTATIC TEST PRESSURE | 1600.0 POUNDS PER SQUARE INCH |
BURST TEST PRESSURE | 3200.0 POUNDS PER SQUARE INCH |
OUTER COVERING ENVIRONMENTAL PROTECTION | FUEL RESISTANT AND |
| WATER RESISTANT |
LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED STEEL WIRE AND |
| 2ND LAYER WRAPPED RUBBER, NATURAL AND |
| OUTER LAYER RUBBER IMPREGNATED BRAIDED COTTON CORD |
MINIMUM INSIDE BENDING RADIUS | 7.375 INCHES |
INSIDE DIAMETER | 0.875 INCHES NOMINAL |
OUTSIDE DIAMETER | 1.234 INCHES NOMINAL |
INSIDE SURFACE CONDITION | SMOOTH |
CONNECTION STYLE | PLAIN 1ST END |
| SWIVEL NUT FLARE 2ND END |
SEAT ANGLE | 30.0 DEGREES 1ST END |
| 37.0 DEGREES 2ND END |
END CONNECTION DESIGN | STRAIGHT 1ST END |
| STRAIGHT 2ND END |
THREAD SERIES DESIGNATOR | UNF 1ST END |
| UNF 2ND END |
NOMINAL THREAD SIZE | 1.000 INCHES 1ST END |
| 1.312 INCHES 2ND END |
THREAD QUANTITY PER INCH | 11-1/2 1ST END |
| 12 2ND END |
THREAD CLASS | 2B 2ND END |
THREAD DIRECTION | RIGHT-HAND 1ST END |
| RIGHT-HAND 2ND END |