| END CONNECTION DESIGN | ELBOW SECOND END |
| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END FLANGE CONSTRUCTION | SOLID FIRST END |
| END FLANGE CONSTRUCTION | SOLID SECOND END |
| BURST TEST PRESSURE | 7000.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | PLAIN W/ GASKET GROOVE (SAE FLANGED HEAD) FIRST END |
| CONNECTION STYLE | PLAIN W/ GASKET GROOVE (SAE FLANGED HEAD) SECOND END |
| CONNECTION TYPE | PLAIN FACE FLANGE FIRST END |
| CONNECTION TYPE | PLAIN FACE FLANGE SECOND END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLANGE OUTSIDE DIAMETER | 1.188 INCHES NOMINAL FIRST END |
| FLANGE OUTSIDE DIAMETER | 1.188 INCHES NOMINAL SECOND END |
| FLANGE THICKNESS | 0.315 INCHES NOMINAL FIRST END |
| FLANGE THICKNESS | 0.315 INCHES NOMINAL SECOND END |
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES FIRST END |
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES SECOND END |
| FLOW ANGLE | 90.0 DEGREES SECOND END |
| HYDROSTATIC TEST PRESSURE | 2000.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 0.500 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED STEEL WIRE AND OUTER LAYER MOLDED RUBBER, SYNTHETIC |
| OPERATING PRESSURE | 1500.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| OUTER COVERING ENVIRONMENTAL PROTECTION | COLD RESISTANT AND HEAT RESISTANT AND OIL RESISTANT AND OZONE RESISTANT |
| OUTSIDE DIAMETER | 0.906 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 17.750 INCHES NOMINAL WORKING |
| MEDIA FOR WHICH DESIGNED | HYDRAULIC FLUID SINGLE RESPONSE |
| MINIMUM INSIDE BENDING RADIUS | 7.000 INCHES |
| SPECIAL FEATURES | EXTERNAL SUPPORT CONSISTS OF SLEEVE |
| TEMP RATING | -40.0 FAHRENHEIT AND 250.0 FAHRENHEIT SINGLE RESPONSE |