| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END CONNECTION DESIGN | ELBOW SECOND END |
| BURST TEST PRESSURE | 3200.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | SWIVEL NUT FLARE SECOND END |
| CONNECTION STYLE | SWIVEL NUT FLARE FIRST END |
| CONNECTION TYPE | THREADED INTERNAL TUBE FIRST END |
| CONNECTION TYPE | THREADED INTERNAL TUBE SECOND END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLOW ANGLE | 90.0 DEGREES SECOND END |
| INSIDE DIAMETER | 0.875 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER RUBBER IMPREGNATED BRAIDED COTTON CORD AND 2ND LAYER BRAIDED STEEL WIRE AND OUTER LAYER RUBBER IMPREGNATED BRAIDED COTTON CORD |
| OUTER COVERING ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND OIL RESISTANT |
| OUTSIDE DIAMETER | 1.230 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 45.000 INCHES NOMINAL OVERALL |
| MEDIA FOR WHICH DESIGNED | ETHYLENE GLYCOL AND FUEL/OIL, HYDROCARBON AND HYDRAULIC FLUID SINGLE RESPONSE |
| MINIMUM INSIDE BENDING RADIUS | 7.375 INCHES |
| NOMINAL THREAD SIZE | 1.312 INCHES FIRST END |
| NOMINAL THREAD SIZE | 1.312 INCHES SECOND END |
| OPERATING PRESSURE | 800.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| SEAT ANGLE | 37.0 DEGREES SECOND END |
| SEAT ANGLE | 37.0 DEGREES FIRST END |
| VACUUM IN TORR | 254.0 |
| TEMP RATING | -40.0 FAHRENHEIT AND 200.0 FAHRENHEIT SINGLE RESPONSE |
| THREAD CLASS | 3B FIRST END |
| THREAD CLASS | 3B SECOND END |
| THREAD DIRECTION | RIGHT-HAND FIRST END |
| THREAD DIRECTION | RIGHT-HAND SECOND END |
| THREAD QUANTITY PER INCH | 12 FIRST END |
| THREAD QUANTITY PER INCH | 12 SECOND END |
| THREAD SERIES DESIGNATOR | UN FIRST END |
| THREAD SERIES DESIGNATOR | UN SECOND END |