CONNECTION TYPE | RAISED FACE FLANGE 1ST END |
MEASURING METHOD AND LENGTH | 30.000 INCHES NOMINAL OVERALL |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
MAXIMUM OPERATING PRESSURE | 100.0 POUNDS PER SQUARE INCH |
HYDROSTATIC TEST PRESSURE | 200.0 POUNDS PER SQUARE INCH |
LAYER COMPOSITION AND LOCATION | OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
MINIMUM INSIDE BENDING RADIUS | 12.000 INCHES |
BOLT CIRCLE DIAMETER | 5.500 INCHES NOMINAL 1ST END |
FLANGE THICKNESS | 0.035 INCHES NOMINAL 1ST END |
INSIDE DIAMETER | 2.975 INCHES NOMINAL |
OUTSIDE DIAMETER | 3.335 INCHES NOMINAL |
INSIDE SURFACE CONDITION | SMOOTH |
CONNECTION STYLE | RAISED 1ST END |
RAISED FACE HEIGHT | 0.062 INCHES NOMINAL 1ST END |
RAISED FACE DIAMETER | 3.791 INCHES NOMINAL 1ST END |
END FLANGE CONSTRUCTION | SOLID 1ST END |
FLANGE STYLE | ROUND W / BOLT HOLES 1ST END |
BOLT HOLE DIAMETER | 0.562 INCHES NOMINAL 1ST END |
FLANGE OUTSIDE DIAMETER | 6.625 INCHES NOMINAL 1ST END |
END CONNECTION DESIGN | STRAIGHT 1ST END |
BOLT HOLE QUANTITY | 8 1ST END |
SPECIAL FEATURES | 90 DEG ELBOW IN THE CENTER |