| END CONNECTION DESIGN | STRAIGHT FIRST END |
| BURST TEST PRESSURE | 12000.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | INVERTED FLARE FIRST END |
| CONNECTION TYPE | THREADED INTERNAL TUBE FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| INSIDE DIAMETER | 0.242 INCHES MINIMUM AND 0.273 INCHES MAXIMUM |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | OUTER LAYER BRAIDED STEEL WIRE |
| OUTSIDE DIAMETER | 0.656 INCHES MINIMUM AND 0.718 INCHES MAXIMUM |
| MEASURING METHOD AND LENGTH | 46.180 INCHES NOMINAL OVERALL |
| MEDIA FOR WHICH DESIGNED | HYDRAULIC FLUID SINGLE RESPONSE |
| NOMINAL THREAD SIZE | 0.438 INCHES FIRST END |
| OPERATING PRESSURE | 2800.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| SEAT ANGLE | 37.0 DEGREES FIRST END |
| SPECIAL FEATURES | INNER CONVEYING TUBE MATERIAL-PLASTIC |
| THREAD CLASS | 2B FIRST END |
| THREAD DIRECTION | RIGHT-HAND FIRST END |
| THREAD QUANTITY PER INCH | 20 FIRST END |
| THREAD SERIES DESIGNATOR | UNF FIRST END |