| END FLANGE CONSTRUCTION | SOLID FIRST END |
| END FLANGE CONSTRUCTION | SOLID SECOND END |
| BOLT CIRCLE DIAMETER | 0.043 INCHES MINIMUM AND 0.450 INCHES MAXIMUM FIRST END |
| BOLT HOLE DIAMETER | 0.280 INCHES MINIMUM AND 0.287 INCHES MAXIMUM FIRST END |
| BOLT HOLE QUANTITY | 2 FIRST END |
| BURST TEST PRESSURE | 180.0 POUNDS PER SQUARE INCH |
| CONNECTION STYLE | PLAIN FIRST END |
| CONNECTION STYLE | PLAIN SECOND END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLANGE LENGTH | 1.695 INCHES NOMINAL FIRST END |
| FLANGE OUTSIDE DIAMETER | 0.626 INCHES NOMINAL SECOND END |
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES SECOND END |
| FLANGE STYLE | OVAL FIRST END |
| FLANGE THICKNESS | 0.030 INCHES NOMINAL SECOND END |
| FLANGE WIDTH | 0.418 INCHES NOMINAL FIRST END |
| FLOW ANGLE | 37.0 DEGREES SECOND END |
| INNER CONVEYING TUBE STYLE | HELICAL CLOSE-PITCH CORRUGATED |
| INSIDE DIAMETER | 0.998 INCHES MINIMUM AND 0.999 INCHES MAXIMUM |
| OPERATING PRESSURE | 120.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| OUTSIDE DIAMETER | 1.060 INCHES NOMINAL |
| MEDIA FOR WHICH DESIGNED | AIR SINGLE RESPONSE |
| MEASURING METHOD AND LENGTH | 6.892 INCHES MINIMUM WORKING AND 6.912 INCHES MAXIMUM WORKING |