| END CONNECTION DESIGN | STRAIGHT FIRST END |
| END CONNECTION DESIGN | ELBOW SECOND END |
| END FLANGE CONSTRUCTION | SPLIT SECOND END |
| END FLANGE CONSTRUCTION | SPLIT FIRST END |
| BOLT HOLE DIAMETER | 0.205 INCHES NOMINAL FIRST END |
| BOLT HOLE DIAMETER | 0.205 INCHES NOMINAL SECOND END |
| BOLT HOLE QUANTITY | 4 FIRST END |
| BOLT HOLE QUANTITY | 4 SECOND END |
| BURST TEST PRESSURE | 6000.0 POUNDS PER SQUARE INCH |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG LENGTH | 0.951 INCHES NOMINAL FIRST END |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG LENGTH | 0.951 INCHES NOMINAL SECOND END |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG WIDTH | 0.951 INCHES NOMINAL FIRST END |
| CENTER TO CENTER DISTANCE BETWEEN BOLT HOLES ALONG WIDTH | 0.951 INCHES NOMINAL SECOND END |
| CONNECTION STYLE | RAISED SWIVEL FIRST END |
| CONNECTION STYLE | RAISED SWIVEL SECOND END |
| CONNECTION TYPE | RAISED FACE FLANGE FIRST END |
| CONNECTION TYPE | RAISED FACE FLANGE SECOND END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FEATURES PROVIDED | ELECTROSTATIC DISCHARGE CAPABILITY |
| FLANGE LENGTH | 1.594 INCHES MINIMUM AND 1.610 INCHES MAXIMUM SECOND END |
| FLANGE LENGTH | 1.594 INCHES MINIMUM AND 1.610 INCHES MAXIMUM FIRST END |
| FLANGE THICKNESS | 0.281 INCHES MINIMUM AND 0.313 INCHES MAXIMUM FIRST END |
| FLANGE THICKNESS | 0.281 INCHES MINIMUM AND 0.313 INCHES MAXIMUM SECOND END |
| FLANGE STYLE | RECTANGULAR (INCLUDES SQUARE) FIRST END |
| FLANGE STYLE | RECTANGULAR (INCLUDES SQUARE) SECOND END |
| FLANGE WIDTH | 1.594 INCHES MINIMUM AND 1.610 INCHES MAXIMUM FIRST END |
| FLOW ANGLE | 90.0 DEGREES SECOND END |
| INSIDE DIAMETER | 0.625 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| LAYER COMPOSITION AND LOCATION | OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
| OUTSIDE DIAMETER | 0.797 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 11.500 INCHES MINIMUM WORKING AND 11.750 INCHES MAXIMUM WORKING |
| MINIMUM INSIDE BENDING RADIUS | 6.500 INCHES |
| OPERATING PRESSURE | 1000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| OUTER COVERING ENVIRONMENTAL PROTECTION | ABRASION RESISTANT |
| RAISED FACE DIAMETER | 1.245 INCHES MINIMUM AND 1.250 INCHES MAXIMUM FIRST END |
| RAISED FACE DIAMETER | 1.245 INCHES MINIMUM AND 1.250 INCHES MAXIMUM SECOND END |
| RAISED FACE HEIGHT | 0.020 INCHES NOMINAL FIRST END |
| RAISED FACE HEIGHT | 0.020 INCHES NOMINAL SECOND END |
| TEMP RATING | -100.0 FAHRENHEIT AND 450.0 FAHRENHEIT SINGLE RESPONSE |