CENTRIFUGAL PUMP DESIGN | AXIAL FLOW |
CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
COOLING METHOD | AIR TO AIR COOLED |
CURRENT RATING IN AMPS | 2.2 |
CURRENT TYPE | AC |
DISCHARGE PRESSURE | 0.0 POUNDS PER SQUARE INCH GAGE |
DISCHARGE CONNECTION QUANTITY | 1 |
DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 1.25-11-1/2 NPT |
DISCHARGE CONNECTION TYPE | THREADED INTERNAL |
ENVIRONMENTAL PROTECTION | SUBMERSIBLE |
FEATURES PROVIDED | SELF-PRIMING |
FREQUENCY IN HERTZ | 60.0 |
INCLOSURE TYPE | FULLY INCLOSED |
MAXIMUM DISCHARGE FLOW RATE | 75.0 GALLONS PER MINUTE |
MEDIA FOR WHICH DESIGNED | WATER, FRESH |
PHASE | SINGLE |
PRIME MOVER COOLING MEDIUM | AIR |
PRIME MOVER POWER RATING | 0.333 HORSEPOWER |
PRIME MOVER QUANTITY | 1 |
PRIME MOVER TYPE | ELECTRIC MOTOR |
PUMP QUANTITY | 1 |
PUMPING ELEMENT OPERATING POSITION | VERTICAL |
OPERATING SPEED AT RATED CAPACITY | 1725.0 REVOLUTIONS PER MINUTE |
SPECIAL FEATURES | 1600 SERIES SUMP PUMP; CLASS 30 CAST IRON CONSTRUCTION; 300 SERIES STAINLESS STEEL HARDWARE |
STAGE QUANTITY | 1 |
TOTAL HEAD | 24.000 FEET |
VOLTAGE IN VOLTS | 115.0 |