| DRIVE TYPE | DIRECT |
| ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
| AIR FLOW RATE | 60.0 CUBIC FEET PER MINUTE NOMINAL |
| AMBIENT TEMP AT FULL RATED POWER | 125.0 CELSIUS |
| DIAMETER | 1.859 INCHES NOMINAL |
| ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
| FEATURES PROVIDED | NONSPARKING |
| FLOW DIRECTION | INWARD |
| FREQUENCY IN HERTZ | 400.0 |
| HOUSING INSIDE DIAMETER | 1.890 INCHES NOMINAL |
| INCLOSURE TYPE | FULLY INCLOSED |
| LENGTH | 1.600 INCHES NOMINAL |
| MATERIAL | ALUMINUM OVERALL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 FLANGE |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 19500.0 |
| PHASE | THREE |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| PRIME MOVER POWER RATING | 0.042 HORSEPOWER |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| QUANTITY | 1 |
| ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| SPECIAL TEST FEATURES | MIL-E-5272,PROCEDURE VI,CONDITION D |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| STAGE QUANTITY | 1 |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
| STYLE DESIGNATOR | FIXED |
| SURFACE TREATMENT | ANODIZE OVERALL |
| TEST DATA DOCUMENT | 06481-900289-15 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |