| DISTANCE FROM PUMP MOUNTING FACE TO ACTUATOR CENTER | 1.730 IN. TO CENTER OF CAM ECCENTRICITY |
| DRAIN FACILITY | NOT INCLUDED |
| ACTUATION METHOD | DIRECT CAM |
| FURNISHED ITEMS AND QUANTITY | GASKET 1 |
| FORDING FEATURE | NOT INCLUDED |
| FSC APPLICATION DATA | ENGINE FUEL SYSTEM,NONAIRCRAFT |
| FUEL FILTER | NOT INCLUDED |
| INLET CONNECTION TYPE/SIZE | FUEL 0.125 IN.-27 NPSF THD SIZE |
| OVERALL LENGTH | 4.680 INCHES MINIMUM AND 4.740 INCHES MAXIMUM |
| OVERALL WIDTH | 3.850 INCHES MINIMUM AND 3.910 INCHES MAXIMUM |
| MAXIMUM STATIC PRESSURE ABOVE OUTLET HEIGHT | 6.5 LB AT 16 IN. AT 1800 RPM |
| MOUNTING TYPE | SAE PREFERRED |
| OUTLET CONNECTION TYPE/SIZE | FUEL 0.125 IN.-27 NPSF THD SIZE |
| OVERALL HEIGHT | 4.740 INCHES MINIMUM AND 4.780 INCHES MAXIMUM |
| PRIMING LEVER | NOT INCLUDED |
| STROKE LENGTH | 0.860 INCHES NOMINAL |
| VACUUM BOOSTER | NOT INCLUDED |