| ACTUATION METHOD | DIRECT CAM |
| DISTANCE FROM PUMP MOUNTING FACE TO ACTUATOR CENTER | 1.556 IN. MAX TO 1.536 IN. MIN OF CAM ECCENTRICITY |
| DRAIN FACILITY | NOT INCLUDED |
| FORDING FEATURE | INCLUDED |
| FSC APPLICATION DATA | ENGINE FUEL SYSTEM COMPONENTS,NONAIRCRAFT |
| FUEL FILTER | NOT INCLUDED |
| FURNISHED ITEMS AND QUANTITY | GASKET 1 |
| INLET CONNECTION TYPE/SIZE | FUEL 1/8 IN.-27 THD SIZE |
| MAXIMUM STATIC PRESSURE ABOVE OUTLET HEIGHT | 4-1/2 PSI AT 16 IN. AT 1800 RPM |
| MOUNTING TYPE | NONSTANDARD |
| OUTLET CONNECTION TYPE/SIZE | FUEL 1/8 IN.-27 THD SIZE |
| OVERALL HEIGHT | 1.875 INCHES NOMINAL |
| OVERALL LENGTH | 2.375 INCHES NOMINAL |
| OVERALL WIDTH | 2.000 INCHES NOMINAL |
| PRIMING LEVER | NOT INCLUDED |
| SPECIAL FEATURES | PENDING USER COORDINATION THIS ITEM TO BE REPLACE BY NSN 2910-00-784-5351; SOS S9C" |
| STROKE LENGTH | 0.850 INCHES MINIMUM AND 0.860 INCHES MAXIMUM |
| VACUUM BOOSTER | NOT INCLUDED |