| DRUM DESIGNATION | LEFT-HAND |
| DRUM DIAMETER AND LOCATION | 20.000 INCHES NOMINAL FIRST DRUM |
| DRUM DIAMETER AND LOCATION | 20.000 INCHES NOMINAL SECOND DRUM |
| DRUM FLANGE TO FLANGE DISTANCE AND LOCATION | 18.000 INCHES NOMINAL FIRST DRUM |
| DRUM FLANGE TO FLANGE DISTANCE AND LOCATION | 18.000 INCHES NOMINAL SECOND DRUM |
| DRUM SURFACE DESIGN | GROOVED |
| DUTY CYCLE | INTERMITTENT |
| BRAKING METHOD | MANUAL |
| COOLING METHOD | ANY ACCEPTABLE |
| CURRENT TYPE | DC |
| FURNISHED ITEMS AND QUANTITY | 1 MOTOR CONTROLLER |
| ENVIRONMENTAL PROTECTION | WATERTIGHT |
| INCLOSURE TYPE | FULLY INCLOSED |
| LOAD LIMIT AT SELECTED SPEED AND DRUM LOCATION | 8600.0 POUNDS SINGLE SPEED FIRST DRUM |
| LOAD LIMIT AT SELECTED SPEED AND DRUM LOCATION | 8600.0 POUNDS SINGLE SPEED SECOND DRUM |
| OPERATION METHOD | POWERED |
| POWER REQUIREMENT RATING | 25.00 HORSEPOWER |
| PRIME MOVER QUANTITY | 1 |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY USE OF GE MOTOR,DWG NO. L-8432003,ANDGE CONTROLLER,DWG NO. K-2290845 |
| VOLTAGE IN VOLTS | 230.0 |
| TRAVEL RATE PER MINUTE | 20.0 FEET |